1.
Klin Monbl Augenheilkd ; 241(4): 347-354, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38653289

ABSTRACT

BACKGROUND: Various yoga positions may have an unfavorable impact on intraocular pressure (IOP) and may therefore be seen as a potential risk factor for the progression of glaucoma. The new "iCare HOME2" is a handheld self-tonometer for IOP measurements outside clinical settings. This is the first study to evaluate the immediate effect of common yoga postures on the IOP of healthy and glaucomatous eyes using the "iCare HOME2" self-tonometer and to compare the time of IOP recovery in both groups. METHODS: This is a single-center, prospective, observational study including 25 healthy and 25 glaucoma patients performing the following yoga positions: "legs up" (Viparita Karani), "bend over" (Uttanasana), "plough pose" (Halasana), and the "down face dog" (Adho Mukha Svanasana) for 90 s each, with a 2-min break in between. IOP was measured with the "iCare HOME2" before, during, and after each position. RESULTS: IOP significantly increased in all eyes in all positions (p < 0.05), showing no statistically significant difference between healthy or glaucomatous eyes (p > 0.05). The mean rise in IOP in healthy subjects was 1.6 mmHg (SD 1.42; p = 0.037), 14.4 mmHg (SD 4.48; p < 0.001), 7.5 mmHg (SD 4.21; p < 0.001), and 16.5 mmHg (SD 3.71; p < 0.001), whereas in glaucoma patients, IOP rose by 2.8 mmHg (SD 2.8; p = 0.017), 11.6 mmHg (SD 3.86; p < 0.001), 6.0 mmHg (SD 2.24; p < 0.001), and 15.1 mmHg (SD 4.44; p < 0.001) during the above listed yoga positions, repsectively. The highest increase in IOP was seen in the down face position, reaching mean IOP values above 31 mmHg in both study groups. IOP elevation was observed immediately after assuming the yoga position, with no significant change during the following 90 s of holding each pose (p > 0.05). All IOP values returned to baseline level in all individuals, with no significant difference between healthy and glaucoma participants. CONCLUSION: Our data show that common yoga positions can lead to an acute IOP elevation of up to 31 mmHg in healthy as well as glaucoma eyes, with higher IOP values during head-down positions. Given that IOP peaks are a major risk factor for glaucomatous optic neuropathy, we generally advise glaucoma patients to carefully choose their yoga exercises. If and to what extent practicing yoga leads to glaucoma progression, however, remains unclear and warrants further research.


Subject(s)
Glaucoma , Intraocular Pressure , Tonometry, Ocular , Yoga , Humans , Intraocular Pressure/physiology , Male , Female , Tonometry, Ocular/methods , Tonometry, Ocular/instrumentation , Middle Aged , Glaucoma/physiopathology , Glaucoma/diagnosis , Glaucoma/therapy , Reproducibility of Results , Adult , Equipment Design , Sensitivity and Specificity , Equipment Failure Analysis , Aged , Prospective Studies
2.
Nutr. clín. diet. hosp ; 44(2): 13-21, Abr. 2024. tab, graf
Article in Spanish | IBECS | ID: ibc-VR-4

ABSTRACT

Introducción: El índice de masa corporal (IMC) es am-pliamente utilizado para diagnosticar estado de nutrición;pero tiene limitaciones porque no evalúa la grasa corporal. Objetivo: Determinar el valor diagnóstico del IMC en com-paración con impedancia bioeléctrica para identificar sobre-peso y obesidad (SpyOb) en adultos jóvenes mexicanos.Material y métodos: Estudio de validación en adultos jó-venes mexicanos. Se midió talla con estadímetro SECA 215,peso y composición corporal con InBody 270 por personal en-trenado. Se realizaron comparaciones por sexo con U deMann Whitney y Chi2; y correlaciones de Spearman para IMCy porcentaje de grasa corporal total (%GCT). Se calculó sen-sibilidad (s) y especificidad (e) con curvas ROC comparandoIMC y %GCT para diagnosticar SpyOb. Análisis se realizó conStata 14 y valores p<0.05 fueron considerados significativos. Resultados: Se evaluaron 351 universitarios con medianade edad de 19 años. El 42.4% fue diagnosticado con SpyObde acuerdo al IMC, y 48.1% fue identificado en esa mismacondición mediante %GCT; con diferencias significativas porsexo sólo en el diagnóstico por %GCT. La correlación entre IMC y %GCT fue alta para la muestra en general (r=0.68) ymuy alta por sexo (r=0.85 hombres y r=0.81 mujeres). ElAUC para diagnosticar obesidad en mujeres fue de 0.90, conalta sensibilidad (100%) y alta especificidad (80.4%), y paradiagnosticar sobrepeso el AUC fue de 0.52 con baja sensibili-dad (31.5%) y especificidad regular (73.1%). El AUC paradiagnosticar obesidad en hombres fue de 0.84, con alta sen-sibilidad (80%) y alta especificidad (88.9%), y para diagnos-ticar sobrepeso el AUC fue de 0.63, con baja sensibilidad(32.5%) y alta especificidad (94.3%).Conclusiones: Se encontró alta y muy alta correlaciónentre IMC y %GCT, tanto en hombres como en mujeres. ElIMC es un indicador útil y confiable para diagnosticar obesi-dad, pero no para diagnosticar sobrepeso en jóvenes adultos mexicanos.(AU)


Background:The Body Mass Index (BMI) is widely usedfor nutritional status assessment; nevertheless, it has limita-tions due to the fact that it doesn’t evaluate the body fat.Objective: Identify the diagnostic value of the BMI versusBioelectrical Impedance to determinate overweight and obe-sity in young Mexican adults.(AU)


Subject(s)
Humans , Male , Female , Body Mass Index , Overweight , Obesity , Nutritional Status , Electric Impedance , Mexico , Sensitivity and Specificity
3.
Talanta ; 273: 125841, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38460421

ABSTRACT

The approach based on a combination of isothermal recombinase polymerase amplification (RPA), 2'-deoxyuridine-5'-triphosphate modified with tyrosine aromatic group (dUTP-Y1), and direct voltammetric detection of RPA product carrying electroactive labels was successfully applied to the potato pathogen Dickeya solani. The artificial nucleotide dUTP-Y1 demonstrated a good compatibility with RPA, enabling by targeting a section of D. solani genome with a unique sequence to produce the full-size modified products at high levels of substitution of dTTP by dUTP-Y1 (up to 80-90 %) in the reaction mixture. The optimized procedure of square wave voltammetry allowed to reliably detect the product generated by RPA at 80 % substitution of dTTP by dUTP-Y1 (dsDNA-Y1) in microliter sample volumes on the surface of disposable carbon screen printed electrodes at the potential of about 0.6 V. The calibration curve for the amplicon detection was linear in coordinates 'Ip, A vs. Log (c, M)' within the 0.05-1 µM concentration range. The limit of detection for dsDNA-Y1 was estimated as 8 nM. The sensitivity of the established electrochemical approach allowed to detect amplicons generated in a single standard 50 µL RPA reaction after their purification with silica-coated magnetic beads. The overall detectability of D. solani with the suggested combination of RPA and voltammetric registration of dsDNA-Y1 can be as low as a few copies of bacterial genome per standard reaction. In total, amplification, purification, and electrochemical detection take about 120-150 min. Considering the potential of direct electrochemical analysis for miniaturization, as well as compliance with low-cost and low-power requirements, the findings provide grounds for future development of microfluidic devices integrating isothermal amplification, amplicon purification and detection based on the tyrosine modified nucleotide for the purpose of 'on-site' detection of various pathogens.


Subject(s)
Dickeya , Polyphosphates , Recombinases , Solanum tuberosum , DNA , Enterobacteriaceae , Nucleotides , Deoxyuridine , Nucleic Acid Amplification Techniques/methods , Sensitivity and Specificity
4.
Altern Ther Health Med ; 30(2): 136-139, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37856803

ABSTRACT

Objective: Knee injuries are very common and may lead to other secondary injuries if effective treatment is lacking. In addition to standardized physical examination, magnetic resonance imaging (MRI) is sometimes considered an aid in the diagnosis of knee trauma. In order to have a more accurate diagnosis of knee injuries, we compared MRI with arthroscopic findings in this study to evaluate the diagnostic accuracy of MRI for meniscal tears and anterior cruciate ligament injuries of the knee. Methods: One hundred and ten patients with suspected meniscal tears and anterior cruciate ligament injuries of the knee who were admitted to our hospital from June 2020 to June 2022 were selected as study subjects, and the clinical data of the patients were retrospectively analyzed. All patients underwent MRI for preoperative diagnosis, and the sensitivity, specificity, MRI findings, and confirmation of diagnosis were compared and analyzed, and the accuracy of MRI in diagnosing meniscal tears and ACL injuries of the knee was analyzed. Results: The mean ACL angle was (98.0 ± 5.4) in the MRI group and (118.0 ± 6.8) in the arthroscopic group, the difference between the two groups was statistically significant P < .05. The mean L/H value of the ACL was (2.12 ± 0.38) in the MRI group and (1.81 ± 0.19) in the arthroscopic group, which was statistically different between the two groups (P < .05). Among the patients, 68 meniscal injuries were found in the MRI examination, including 45 cases of knee meniscal tears and 23 cases of anterior cruciate ligament injuries. The sensitivity, specificity, positive and negative predictive values, agreement rate, kappa value, and Youden index of MRI in diagnosing meniscal tears and ACL injuries were all high. Conclusions: In terms of sensitivity and accuracy, MRI is an excellent imaging technique for the diagnosis of meniscal tears and anterior cruciate ligament injuries of the knee.


Subject(s)
Anterior Cruciate Ligament Injuries , Knee Injuries , Meniscus , Tibial Meniscus Injuries , Humans , Anterior Cruciate Ligament Injuries/diagnostic imaging , Anterior Cruciate Ligament Injuries/complications , Retrospective Studies , Sensitivity and Specificity , Arthroscopy/methods , Tibial Meniscus Injuries/diagnostic imaging , Tibial Meniscus Injuries/complications , Knee Injuries/diagnostic imaging , Knee Injuries/complications , Magnetic Resonance Imaging/methods
5.
Plant Dis ; 108(1): 35-40, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37528342

ABSTRACT

The pathogen Colletotrichum siamense causes tea anthracnose, resulting in economic losses to the Chinese tea industry. To effectively diagnose this pathogen in the field, we developed a loop-mediated isothermal amplification (LAMP) method using highly specific primers with a sensitivity of 1 pg/µl designed for amplifying the CAL gene, which was 10 times higher than that of conventional PCR. Additionally, to improve the method for obtaining DNA samples required for on-site diagnosis, we used the filter-disc DNA extraction method, which does not require special instruments and can be completed in a few minutes, and found that it effectively meets the requirements for the LAMP reaction. Finally, we combined LAMP with a filter-disc DNA extraction method (FDE-LAMP) to diagnose different degrees of disease in inoculated samples and 20 samples from the field. The results showed that the procedure had sufficient sensitivity for pathogen detection. Therefore, the FDE-LAMP procedure could greatly contribute to managing and preventing tea anthracnose in the field.


Subject(s)
Colletotrichum , DNA , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , Tea , Sensitivity and Specificity
6.
Article in English | MEDLINE | ID: mdl-38096645

ABSTRACT

Endometriosis is a complex chronic inflammatory process characterised by the presence of endometrial-like glandular tissue outside the uterine cavity, typically within the pelvic structures. This condition affects up to 10-15 % of women and those assigned female at birth, and can result in chronic pelvic pain and in/subfertility. Treatment goals include medical, surgical options and alternative therapies. Transvaginal ultrasound (TVUS) is the currently recommended first line investigation for endometriosis with magnetic resonance imaging (MRI) reserved for those with equivocal ultrasound findings. In this paper, we aim to outline the commonly seen sonographic appearances of endometriosis divided into anterior, middle and posterior pelvic compartments. Limitations to ultrasound imaging include high operator dependence and patient factors. New imaging techniques and research into the utility of artificial intelligence (AI) into the detection of endometriosis is currently underway, with possibility of reduced diagnostic delay and better patient outcomes.


Subject(s)
Endometriosis , Infertility, Female , Infant, Newborn , Female , Humans , Endometriosis/complications , Endometriosis/diagnostic imaging , Infertility, Female/diagnostic imaging , Infertility, Female/etiology , Artificial Intelligence , Delayed Diagnosis , Ultrasonography/methods , Sensitivity and Specificity
7.
Int. j. morphol ; 41(6): 1775-1780, dic. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1528801

ABSTRACT

SUMMARY: The Innervation Zones (IZ) correspond to clusters of neuromuscular junctions. The traditional method of locating IZs through voluntary muscle contractions may not be feasible in individuals with motor disorders. Imposed contractions by electrostimulation are an alternative. However, there is limited evidence regarding the factors that affect inter-evaluator concordance and the number of localized IZs when using imposed contraction. The main objective of this research was to determine the effect of the amplitude of compound motor action potentials (CMAPs) containing the M-wave on inter-evaluator agreement. As a secondary objective, was investigate the effect on the number of detected IZs. Twenty-four healthy volunteers (age: 21.2 ± 1.5years, weight: 67.4 ± 13.2kg, height: 1.68 ± 0.80m) participated in the study. Electrostimulation was applied to the tibial nerve to induce contraction of the medial gastrocnemius. The IZ were identified based on the M-wave recorded through multichannel electromyography. A receiver operating characteristic (ROC) analysis was conducted to assess sensitivity and specificity in detecting the IZs. Inter-rater agreement was evaluated using a two-way mixed effects test to determine the intraclass correlation coefficients (ICC). A p-value less than 0.05 was considered statistically significant. The ROC analysis revealed that for both evaluators, a specificity of 95% was achieved with an amplitude ≥30 %. The area under the ROC curve was 0.980 [0.964, 0.996], indicating a strong influence of CMAP amplitude on detection of IZs. The highest level of agreement (ICC = 0.788 [0.713, 0.844]) among the evaluators was observed with CMAP amplitudes equal to or greater than 80 % of the maximum M-wave. The findings of this study demonstrate that both the number and the inter-evaluator concordance for detecting IZs using imposed contractions are strongly influenced by the amplitude of the M-wave. Higher M-wave amplitudes were associated with improved concordance and increased IZ detection, making it crucial to standardize amplitude settings for reliable outcomes.


Las Zonas de Inervación (IZ) corresponden a grupos de uniones neuromusculares. El método tradicional para localizar IZs mediante contracciones musculares voluntarias puede no ser factible en personas con trastornos motores. Las contracciones impuestas mediante electro estimulación son una alternativa. Sin embargo, existe poca evidencia sobre los factores que afectan la concordancia entre evaluadores y el número de IZs localizadas al usar este tipo de contracciones. El objetivo de esta investigación fue determinar el efecto de la amplitud de los potenciales de acción motores compuestos (PAMCs) que contienen la onda M sobre la concordancia entre evaluadores. Como objetivo secundario, se investigó el efecto sobre el número de IZs detectadas. Veinticuatro voluntarios sanos (edad: 21.2 ± 1.5 años, peso: 67.4 ± 13.2 kg, altura: 1.68 ± 0.80 m) participaron en el estudio. Se aplicó electroestimulación al nervio tibial para inducir la contracción del gastrocnemio medial. Las IZs se identificaron según la onda M registrada mediante electromiografía multicanal. Se realizó un análisis de curva de las característica del receptor (ROC) para evaluar la sensibilidad y especificidad en la detección de las IZs. La concordancia entre evaluadores se evaluó utilizando una prueba de efectos mixtos de dos vías para determinar los coeficientes de correlación intraclase (ICC). Se consideró un valor de p menor que 0.05 como estadísticamente significativo. El análisis ROC reveló que para ambos evaluadores se logró una especificidad del 95% con una amplitud ≥30 %. El área bajo la curva ROC fue de 0.980 [0.964, 0.996], lo que indica una fuerte influencia de la amplitud del CMAP en la detección de las IZs. El nivel más alto de concordancia (ICC = 0.788 [0.713, 0.844]) entre los evaluadores se observó con amplitudes de CMAP iguales o mayores al 80 % de la onda M máxima. Los hallazgos de este estudio demuestran que tanto el número como la concordancia entre evaluadores para detectar IZs mediante contracciones impuestas están fuertemente influenciados por la amplitud de la onda M. Las amplitudes más altas de la onda M se asociaron con una concordancia mejorada y un aumento en la detección de IZs, lo que hace crucial estandarizar los ajustes de amplitud para obtener resultados confiables.


Subject(s)
Humans , Male , Female , Young Adult , Muscle, Skeletal/innervation , Observer Variation , ROC Curve , Sensitivity and Specificity , Electromyography/methods , Muscle Contraction
8.
Int J Mol Sci ; 24(24)2023 Dec 08.
Article in English | MEDLINE | ID: mdl-38139102

ABSTRACT

Due to the limitations of conventional Brucella detection methods, including safety concerns, long incubation times, and limited specificity, the development of a rapid, selective, and accurate technique for the early detection of Brucella in livestock animals is crucial to prevent the spread of the associated disease. In the present study, we introduce a magnetic nanoparticle marker-based biosensor using frequency mixing magnetic detection for point-of-care testing and quantification of Brucella DNA. Superparamagnetic nanoparticles were used as magnetically measured markers to selectively detect the target DNA hybridized with its complementary capture probes immobilized on a porous polyethylene filter. Experimental conditions like density and length of the probes, hybridization time and temperature, and magnetic binding specificity, sensitivity, and detection limit were investigated and optimized. Our sensor demonstrated a relatively fast detection time of approximately 10 min, with a detection limit of 55 copies (0.09 fM) when tested using DNA amplified from Brucella genetic material. In addition, the detection specificity was examined using gDNA from Brucella and other zoonotic bacteria that may coexist in the same niche, confirming the method's selectivity for Brucella DNA. Our proposed biosensor has the potential to be used for the early detection of Brucella bacteria in the field and can contribute to disease control measures.


Subject(s)
Brucella , Brucellosis , Magnetite Nanoparticles , Animals , Brucella/genetics , Brucellosis/diagnosis , Brucellosis/microbiology , DNA , DNA Primers/genetics , Sensitivity and Specificity
9.
Int J Med Sci ; 20(13): 1698-1704, 2023.
Article in English | MEDLINE | ID: mdl-37928876

ABSTRACT

Background: Conventional methods are low in positive rates and time-consuming for ascites pathogen detection in patients with end-stage liver disease (ESLD). With many advantages, metagenomic next-generation sequencing (mNGS) may be a good alternative method. However, the related studies are still lacking. Methods: Ascites from 50 ESLD patients were sampled for pathogen detection using mNGS and conventional methods (culture and polymorphonuclear neutrophils detection) in this prospective observational study. Results: Forty-two samples were detected positive using mNGS. 29 strains of bacteria, 11 strains of fungi, and 9 strains of viruses were detected. 46% of patients were detected to be co-infected with 2 or more pathogens by mNGS. Moreover, mNGS showed similar and high positive rates in ESLD patients with different clinical characteristics. Compared to conventional methods, mNGS had higher positivity rates (84% vs. 20%, P<0.001), sensitivity (45.2% vs. 23.8%, P=0.039), broader pathogen spectrum, shorter detection time (24 hours vs. 3-7 days), but lower specificity (25% vs 100%, P = 0.010). Furthermore, compared to conventional methods, mNGS showed similar consistence with final diagnosis (42% vs. 36%, P=0.539). Conclusions: mNGS may be a good supplement for conventional methods and helpful to early etiological diagnosis of peritonitis, and thus improve ESLD patients' survival.


Subject(s)
End Stage Liver Disease , Peritonitis , Humans , Ascites , High-Throughput Nucleotide Sequencing , Peritonitis/diagnosis , Peritonitis/etiology , Dietary Supplements , Sensitivity and Specificity
10.
Dtsch Med Wochenschr ; 148(19): 1227-1235, 2023 09.
Article in German | MEDLINE | ID: mdl-37793615

ABSTRACT

Molecular diagnostic tools have changed the approach to the detection of Mycobacterium tuberculosis and associated drug-resistance substantially. PCR-based technologies allow a more rapid detection with higher diagnostic sensitivity in pulmonary and extrapulmonary specimens. However, a real point of care test, which needs minimal technical resources remains missing. Genome sequencing technologies are currently changing tuberculosis drug resistance testing, and for some questions are replacing phenotypic drug resistance testing, based on culture.New evidence on treatment for drug-sensitive tuberculosis allows shortening of treatment to 4 months, or in selected cases even to 2 months based on the use of fluoroquinolones, high dose rifamycins and newly developed TB medicines.Such developments will very likely simplify the management of tuberculosis, although prevention remains the most important pillar of any tuberculosis related public health strategy.


Subject(s)
Mycobacterium tuberculosis , Tuberculosis, Multidrug-Resistant , Tuberculosis, Pulmonary , Tuberculosis , Humans , Sensitivity and Specificity , Tuberculosis, Pulmonary/diagnosis , Tuberculosis, Pulmonary/drug therapy , Mycobacterium tuberculosis/genetics , Tuberculosis/drug therapy , Polymerase Chain Reaction , Tuberculosis, Multidrug-Resistant/diagnosis , Tuberculosis, Multidrug-Resistant/drug therapy , Antitubercular Agents/therapeutic use , Microbial Sensitivity Tests
11.
Radiologia (Engl Ed) ; 65(5): 402-413, 2023.
Article in English | MEDLINE | ID: mdl-37758331

ABSTRACT

OBJECTIVE: To evaluate the behavior of adrenal adenomas and metastases with dual-energy CT, analyzing the attenuation coefficient in monochromatic images at three different levels of energy (45, 70, and 140 keV) and the tissue concentrations of fat, water, and iodine in material density maps, with the aim of establishing optimal cutoffs for differentiating between these lesions and comparing our results against published evidence. MATERIALS AND METHODS: This retrospective case-control study included oncologic patients diagnosed with adrenal metastases in the 6-12 months prior to the study who were followed up in our hospital between January and June 2020. For each case (patient with metastases) included in the study, we selected a control (patient with an adrenal adenoma) with a nodule of similar size. All patients were studied with a rapid-kilovoltage-switching dual-energy CT scanner, using a biphasic acquisition protocol. We analyzed the concentration of iodine in paired water-iodine images, the concentration of fat in the paired water-fat images, and the concentration of water in the paired iodine-water and fat-water images, in both the arterial and portal phases. We also analyzed the attenuation coefficient in monochromatic images (at 55, 70, and 140 keV) in the arterial and portal phases. RESULTS: In the monochromatic images, in both the arterial and portal phases, the attenuation coefficient at all energy levels was significantly higher in the group of patients with metastases than in the group of patients with adenomas. This enabled us to calculate the optimal cutoffs for classifying lesions as adenomas or metastases, except for the arterial phase at 55 KeV, where the area under the receiver operating characteristic curve (AUC) for the estimated threshold (0.68) was not considered accurate enough to classify the lesions. For the arterial phase at 70 keV, the AUC was 0.76 (95% CI: 0.663‒0.899); the optimal cutoff (42.4 HU) yielded 92% sensitivity and 60% specificity. For the arterial phase at 140 keV, the AUC was 0.94 (95% CI: 0.894‒0.999); the optimal cutoff (18.9 HU) yielded 88% sensitivity and 94% specificity). For the portal phase at 55 keV, the AUC was 0.76 (95% CI: 0.663‒0.899); the optimal cutoff (95.4 HU) yielded 68% sensitivity and 84% specificity. For the portal phase at 70 keV, the AUC was 0.82 (95% CI: 0.757‒0.955); the optimal cutoff (58.4 HU) yielded 80% sensitivity and 84% specificity. For the portal phase at 140 keV, the AUC was 0.9 (95% CI: 0.834‒0.987); the optimal cutoff (16.35 HU) yielded 96% sensitivity and 84% specificity. In the material density maps, in the arterial phase, significant differences were found only for the iodine-water pair, where the concentration of water was higher in the group with metastases (1018.8 ±â€¯7.6 mg/cm3 vs. 998.6 ±â€¯8.0 mg/cm3 for the group with adenomas, p < 0.001). The AUC was 0.97 (95% CI: 0.893‒0.999); the optimal cutoff (1012.5 mg/cm3) yielded 88% sensitivity and 96% specificity. The iodine-water pair was also significantly higher in metastases (1019.7 ±â€¯12.1 mg/cm3 vs. 998.5 ±â€¯9.1 mg/cm3 in adenomas, p < 0.001). The AUC was 0.926 (95% CI: 0.807‒0.977); the optimal cutoff (1009.5 mg/cm3) yielded 92% sensitivity and 92% specificity. Although significant results were also observed for the fat-water pair in the portal phase, the AUC was insufficient to enable a sufficiently accurate cutoff for classifying the lesions. No significant differences were found in the fat-water maps or iodine-water maps in the arterial or portal phase or in the water-fat map in the arterial phase. CONCLUSIONS: Monochromatic images show differences between the behavior of adrenal adenomas and metastases in oncologic patients studied with intravenous-contrast-enhanced CT, where the group of metastases had higher attenuation than the group of adenomas in both the arterial and portal phases; this pattern is in line with the evidence published for adenomas. Nevertheless, to our knowledge, no other publications report cutoffs for this kind of differentiation in contrast-enhanced monochromatic images obtained in rapid-kilovoltage-switching dual-energy CT scanners, and this is the first new contribution of our study. Regarding the material density maps, our results suggest that the water-iodine pair is a good tool for differentiating between adrenal adenomas and metastases, in both the arterial and portal phases. We propose cutoffs for differentiating these lesions, although to our knowledge no cutoffs have been proposed for portal-phase contrast-enhanced images obtained with rapid-kilovoltage-switching dual-energy CT scanners.


Subject(s)
Adenoma , Iodine , Humans , Retrospective Studies , Case-Control Studies , Tomography, X-Ray Computed/methods , Sensitivity and Specificity , Adenoma/diagnostic imaging , Adenoma/pathology , Water
12.
Virology ; 587: 109872, 2023 10.
Article in English | MEDLINE | ID: mdl-37657354

ABSTRACT

Reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed for detection of groundnut bud necrosis virus (GBNV) causing potato stem necrosis disease. The isothermal temperatures, reaction periods and concentrations of reaction mixture were optimized where, the assay worked well at 65 °C for 50 min, 6 U of WarmStart Bst 2.0 DNA polymerase, 1.4 mM dNTPs and 2.0 mM MgSO4. The optimized assay proved to be specific to GBNV with no cross reactivity to other viruses infecting potato in India. The specificity of RT-LAMP assay was found to be 100 fold more sensitive than that of RT-PCR. The developed assay was applied for the detection of GBNV from 80 potato leaf samples where 24 samples were found infected which was confirmed by RT-PCR. It was concluded that the RT-LAMP assay developed for detection of GBNV was specific, sensitive and suitable for its use in virus indexing under potato seed production programme.


Subject(s)
Solanum tuberosum , Viruses , Reverse Transcription , Nucleic Acid Amplification Techniques , Sensitivity and Specificity
13.
Gynecol Endocrinol ; 39(1): 2247098, 2023 Aug 09.
Article in English | MEDLINE | ID: mdl-37573873

ABSTRACT

BACKGROUND: Anti-Müllerian hormone (AMH) has recently emerged as a promising biomarker for the detection of polycystic ovarian morphology. In polycystic ovary syndrome (PCOS), an elevated level of AMH has been suggested to add value to the Rotterdam criteria in cases of diagnostic uncertainty. In this study, we evaluated the correlation between AMH and PCOS, and the potential role of AMH in PCOS diagnosis. METHODS: A case-control study was performed on a total of 200 females, 100 of which were diagnosed with PCOS as per Rotterdam revised criteria (2003) and 100 as the control (non-PCOS group). Patient medical records were therefore retrieved for clinical, biochemical and ultrasound markers for PCOS diagnosis. Sensitivity, specificity, area under receiver operating characteristic (AUROC) curve, and multivariate linear regression models were applied to analyze our data. RESULTS: Mean serum levels of LH and AMH, and LH/FSH ratio were significantly different between compared groups. In the PCOS group, the mean serum AMH level was 6.78 ng/mL and LH/FSH ratio was 1.53 while those of controls were 2.73 ng/mL and 0.53, respectively (p < .001). The most suitable compromise between 81% specificity and 79% sensitivity was obtained with a cutoff value of 3.75 ng/mL (26.78 pmol/L) serum AMH concentration for PCOS prediction, with an AUROC curve of 0.9691. CONCLUSION: Serum AMH cutoff level of 3.75 ng/mL was identified as a convenient gauge for the prediction of PCOS and an adjuvant to the Rotterdam criteria.


Subject(s)
Anti-Mullerian Hormone , Polycystic Ovary Syndrome , Adult , Female , Humans , Anti-Mullerian Hormone/blood , Follicle Stimulating Hormone/blood , Luteinizing Hormone/blood , Polycystic Ovary Syndrome/blood , Polycystic Ovary Syndrome/diagnosis , Polycystic Ovary Syndrome/pathology , Prolactin/blood , Sensitivity and Specificity , Vitamin D/blood , Case-Control Studies , Menstruation Disturbances/pathology
14.
Int J Mol Sci ; 24(13)2023 Jun 27.
Article in English | MEDLINE | ID: mdl-37445904

ABSTRACT

Portulaca oleracea (PO) is a commonly known medicinal crop that is an important ingredient for traditional Chinese medicine (TCM) due to its use as a vegetable in the diet. PO has been recorded to be frequently adulterated by other related species in the market of herbal plants, distorting the PO plant identity. Thus, identification of the botanical origin of PO is a crucial step before pharmaceutical or functional food application. In this research, a quick assay named "loop-mediated isothermal amplification (LAMP)" was built for the specific and sensitive authentication of PO DNA. On the basis of the divergences in the internal transcribed spacer 2 (ITS2) sequence between PO and its adulterant species, the LAMP primers were designed and verified their specificity, sensitivity, and application for the PO DNA authentication. The detection limit of the LAMP assay for PO DNA identification specifically was 100 fg under isothermal conditions at 63 °C for 30 min. In addition, different heat-processed PO samples can be applied for use in PO authentication in the LAMP assay. These samples of PO were more susceptible to the effect of steaming in authentication by PCR than boiling and drying treatment. Furthermore, commercial PO samples pursued from herbal markets were used to display their applicability of the developed LAMP analysis for PO postharvest authentication, and the investigation found that approximately 68.4% of PO specimens in the marketplace of herbal remedies were adulterated. In summary, the specific, sensitive, and rapid LAMP assay for PO authentication was first successfully developed herein, and its practical application for the inspection of adulteration in PO samples from the herbal market was shown. This LAMP assay created in this study will be useful to authenticate the botanical origin of PO and its commercial products.


Subject(s)
Plants, Medicinal , Portulaca , Portulaca/genetics , Plants, Medicinal/genetics , Nucleic Acid Amplification Techniques , Polymerase Chain Reaction , DNA Primers/genetics , DNA , Sensitivity and Specificity
15.
Zhonghua Yu Fang Yi Xue Za Zhi ; 57(7): 1047-1058, 2023 Jul 06.
Article in Chinese | MEDLINE | ID: mdl-37482740

ABSTRACT

Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.


Subject(s)
Diabetes Mellitus , Pregnancy , Child , Humans , Female , Glycated Hemoglobin , Cohort Studies , Diabetes Mellitus/diagnosis , Sensitivity and Specificity , ROC Curve
16.
Colorectal Dis ; 25(7): 1371-1380, 2023 07.
Article in English | MEDLINE | ID: mdl-37264714

ABSTRACT

BACKGROUND: Anastomotic leakage (AL) as a result of creation of a colorectal/anal anastomosis still represents a frequent complication of colorectal surgery, with short- and long-term consequences on postoperative morbidity, quality of life and oncological outcomes. However, early diagnosis of AL may result in improved outcomes. The aims of this study were to evaluate the diagnostic accuracy of water-soluble contrast enema (WSCE), contrast enema computed tomography (CECT) and endoscopy in identifying AL and to identify the diagnostic procedure that is most accurate. METHODS: A systematic review and meta-analysis of 19 studies accounting for a total of 25 tests reporting diagnostic accuracy estimates was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines up to June 2021. For the diagnostic tests we evaluated the pooled estimates and conducted pairwise comparisons. RESULTS: For WSCE, the pooled sensitivity was 0.50, the pooled specificity was 0.99 and the area under the curve (AUC) was 0.91. For endoscopy, the pooled sensitivity was 0.69, specificity was 1.00 and AUC was 0.99. The pooled sensitivity and specificity for CECT were 0.89 and 1.00, respectively; the AUC was 0.99. The comparison between CECT and WSCE highlighted a significantly greater sensitivity (p = 0.04) for CECT, whereas no difference was found for specificity. Compared with CECT, endoscopy was not significantly more accurate in terms of either sensitivity or specificity. Endoscopy was found to be significantly more specific than WSCE (p = 0.031) but no difference was found for sensitivity. CONCLUSION: Water-soluble contrast enema, endoscopy and CECT have an elevated diagnostic accuracy. However, WSCE is less accurate than either endoscopy or CECT. Although greater sensitivity was demonstrated for CECT compared with endoscopy, this was not significant.


Subject(s)
Anastomotic Leak , Proctectomy , Humans , Anastomotic Leak/diagnostic imaging , Anastomotic Leak/etiology , Contrast Media , Quality of Life , Tomography, X-Ray Computed , Sensitivity and Specificity , Endoscopy, Gastrointestinal , Enema/methods , Water
17.
PLoS Negl Trop Dis ; 17(5): e0011071, 2023 05.
Article in English | MEDLINE | ID: mdl-37196017

ABSTRACT

BACKGROUND: Soil-transmitted helminth (STH) control programs currently lack evidence-based recommendations for cost-efficient survey designs for monitoring and evaluation. Here, we present a framework to provide evidence-based recommendations, using a case study of therapeutic drug efficacy monitoring based on the examination of helminth eggs in stool. METHODS: We performed an in-depth analysis of the operational costs to process one stool sample for three diagnostic methods (Kato-Katz, Mini-FLOTAC and FECPAKG2). Next, we performed simulations to determine the probability of detecting a truly reduced therapeutic efficacy for different scenarios of STH species (Ascaris lumbricoides, Trichuris trichiura and hookworms), pre-treatment infection levels, survey design (screen and select (SS); screen, select and retest (SSR) and no selection (NS)) and number of subjects enrolled (100-5,000). Finally, we integrated the outcome of the cost assessment into the simulation study to estimate the total survey costs and determined the most cost-efficient survey design. PRINCIPAL FINDINGS: Kato-Katz allowed for both the highest sample throughput and the lowest cost per test, while FECPAKG2 required both the most laboratory time and was the most expensive. Counting of eggs accounted for 23% (FECPAKG2) or ≥80% (Kato-Katz and Mini-FLOTAC) of the total time-to-result. NS survey designs in combination with Kato-Katz were the most cost-efficient to assess therapeutic drug efficacy in all scenarios of STH species and endemicity. CONCLUSIONS/SIGNIFICANCE: We confirm that Kato-Katz is the fecal egg counting method of choice for monitoring therapeutic drug efficacy, but that the survey design currently recommended by WHO (SS) should be updated. Our generic framework, which captures laboratory time and material costs, can be used to further support cost-efficient choices for other important surveys informing STH control programs. In addition, it can be used to explore the value of alternative diagnostic techniques, like automated egg counting, which may further reduce operational costs. TRIAL REGISTRATION: ClinicalTrials.gov NCT03465488.


Subject(s)
Helminthiasis , Helminths , Animals , Humans , Ascaris lumbricoides , Feces , Helminthiasis/drug therapy , Helminthiasis/diagnosis , Sensitivity and Specificity , Soil , Trichuris
18.
Front Cell Infect Microbiol ; 13: 1136588, 2023.
Article in English | MEDLINE | ID: mdl-37009509

ABSTRACT

Background: Community-acquired pneumonia (CAP) is an extraordinarily heterogeneous illness, both in the range of responsible pathogens and the host response. Metagenomic next-generation sequencing (mNGS) is a promising technology for pathogen detection. However, the clinical application of mNGS for pathogen detection remains challenging. Methods: A total of 205 patients with CAP admitted to the intensive care unit were recruited, and broncho alveolar lavage fluids (BALFs) from 83 patients, sputum samples from 33 cases, and blood from 89 cases were collected for pathogen detection by mNGS. At the same time, multiple samples of each patient were tested by culture. The diagnostic performance was compared between mNGS and culture for pathogen detection. Results: The positive rate of pathogen detection by mNGS in BALF and sputum samples was 89.2% and 97.0%, which was significantly higher (P < 0.001) than that (67.4%) of blood samples. The positive rate of mNGS was significantly higher than that of culture (81.0% vs. 56.1%, P = 1.052e-07). A group of pathogens including Mycobacterium abscessus, Chlamydia psittaci, Pneumocystis jirovecii, Orientia tsutsugamushi, and all viruses were only detected by mNGS. Based on mNGS results, Escherichia coli was the most common pathogen (15/61, 24.59%) of non-severe patients with CAP, and Mycobacterium tuberculosis was the most common pathogen (21/144, 14.58%) leading to severe pneumonia. Pneumocystis jirovecii was the most common pathogen (26.09%) in severe CAP patients with an immunocompromised status, which was all detected by mNGS only. Conclusion: mNGS has higher overall sensitivity for pathogen detection than culture, BALF, and sputum mNGS are more sensitive than blood mNGS. mNGS is a necessary supplement of conventional microbiological tests for the pathogen detection of pulmonary infection.


Subject(s)
Community-Acquired Infections , Pneumonia , Humans , Pneumonia/diagnosis , High-Throughput Nucleotide Sequencing , Bronchoalveolar Lavage Fluid , Community-Acquired Infections/diagnosis , Dietary Supplements , Escherichia coli , Metagenomics , Sensitivity and Specificity
19.
Altern Ther Health Med ; 29(5): 238-241, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37052970

ABSTRACT

Objective: The study aims to explore the correlation between the expression levels of peptidylarginine deiminase 4 (PADI4), guanylate binding protein 1 (GBP1), miR-215, and tumor mutational burden (TMB) and clinical features and prognosis of lung cancer. Methods: A total of 156 patients with lung cancer admitted to our hospital from July 2021 to March 2022 were selected. Clinical characteristics of patients were collected and PADI4, GBP1, miR-215, and TMB levels were detected. The correlation between the expression levels of PADI4, GBP1, miR-215, and TMB and the clinical characteristics of lung cancer was analyzed. The predictive value of the expression levels of PADI4, GBP1, miR-215, and TMB for lung cancer prognosis was analyzed by the receiver operator characteristic (ROC) curve. Results: The expression levels of PADI4 and GBP1 were significantly different with respect to smoking history and histopathological type of lung cancer (P < .05). The expression levels of miR-215 and TMB were significantly different in terms of age, smoking history, lymph node metastasis, and tumor node metastasis (TNM) stage of lung cancer (P < .05). ROC curve results showed that the area under the curve (AUC) of PADI4, GBP1, miR-215, and TMB combined to predict the prognosis of lung cancer was 0.814 (0.789-0.912), which was higher than the diagnostic efficacy of single biomarker (P < .05). Its sensitivity and specificity were 85.75% and 89.34%, respectively. Conclusions: The expression levels of PADI4, GBP1, miR-215, and TMB are correlated with the clinical characteristics and prognosis of lung cancer, and can be used as prognostic markers.


Subject(s)
Lung Neoplasms , MicroRNAs , Humans , Biomarkers, Tumor/genetics , GTP-Binding Proteins/metabolism , Lung Neoplasms/diagnosis , Lung Neoplasms/genetics , MicroRNAs/genetics , MicroRNAs/metabolism , Prognosis , Sensitivity and Specificity
20.
Altern Ther Health Med ; 29(5): 153-157, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37052971

ABSTRACT

Context: Tuberculous pleurisy (TP) is the most common manifestation of extrapulmonary tuberculosis and the most frequent cause of pleural effusion (PE). Clinicians make a definitive diagnosis of TP based on the isolation of the mycobacterium tuberculosis (MTB) from PE or a pleural biopsy. Since the currently available tests for TP all have limitations in making a definitive diagnosis, clinicians urgently need new diagnostic tests. Objective: The study intended to compare the value in clinically diagnosing TP of the paraffin-embedded sample test (PEST), using pleural-effusion samples; an adenosine deaminase assay (ADA) using pleural fluid; and the T cell enzyme-linked immunospot test (T-SPOT), using peripheral-blood. Design: The research team performed a retrospective observational study. Setting: The study took place at the Sir Run Run Hospital, Nanjing Medical University in Nanjing, Jiangsu, China. Participants: Participants were 37 patients with suspected TP who had been admitted to the hospital between September 2018 and December 2022. Outcome Measures: The research team assessed the diagnostic performance of PEST, ADA, and T-SPOT in the TP group, calculating the positive rate, sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of the tests. Results: Among the 37 participants, the testing confirmed that 24 had TP (64.86%), with 13 not having TP (35.14%). The PEST test produced a sensitivity of 83.3% for TP, with 20 out of 24 participants in the TP group testing positive (95% CI: 61.8 to 94.5), which was superior to the ADA, with only 9 out of the 24 participants (37.5%) in the TP group testing positive (95% CI: 19.6 to 59.2), with P < .001. Conclusions: The PEST test possesses a high diagnostic value, and clinicians can use it as a time-saving, noninvasive, and highly sensitive method for TP diagnosis. It can be adjunct method to the currently used tests for diagnosing TP. A combination of several detection methods could promote effective treatment.


Subject(s)
Pleural Effusion , Tuberculosis, Extrapulmonary , Tuberculosis, Pleural , Humans , Tuberculosis, Pleural/diagnosis , Tuberculosis, Pleural/pathology , Paraffin Embedding , Sensitivity and Specificity , Pleural Effusion/diagnosis , Pleural Effusion/microbiology